FD580 Ultrasonic Flaw Detector

$4,950.00

The FD580 digital ultrasonic  flaw detector combines conventional flaw detection capabilities with a portable instrument of moderate weight.  Flaw detection is a form of non-destructive testing used in many industries including aerospace, automotive, steel, construction and transportation sectors.

The FD580 digital ultrasonic flaw detector combines conventional flaw detection capabilities with a portable instrument of moderate weight.  Flaw detection is a form of non-destructive testing used in many industries including aerospace, automotive, steel, construction and transportation sectors.

 

Features

  • Automatic transducer calibration, zero offset and/or velocity
  • Automatic gain control, peak hold and peak memory
  • Automatic display of precise flaw location
  • Ten independent setups; any criterion can be input freely, no test block required for proceeding
  • Manual B-Scan
  • High-speed capture and very low noise
  • Two gate settings and alarm indication
  • Automatic generation of DAC and AVG curves
  • Display-freeze capability
  • Angles and K-values may be inputted
  • Lock/unlock system parameters
  • Auto power-off and screen savers
  • Electronic clock calendar
  •  Solid metal housing
  • High contrast viewing of the waveform from bright, direct sunlight to complete darkness and easy to read from all angles
  • Large memory of 300 A-Scan waveforms and 30,000 thickness values.
  • RS232 communication interface ; reports can be exported to Excel
  • Powerful embedded software which can be online-updated
  • Li battery

Specifications

Scanning:

  • Range: 2.5mm to 10,000mm
  • Stage: 2.5, 5, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100, 150, 200, 250, 300, 350, 400, 450,
    500, 600, 700, 800, 900, 1,000, 2,000, 3,000, 4,000, 5,000, 6,000, 7,000, 8,000,
    9,000 and 10,000mm
  • Step:0.1mm (from 2.5 mm to 99.9mm),1mm (from 100mm to 10,000mm)
  • Display delay
  • D-delay range: -20 to +3400µs
  • Stage: -20, -10, 0.0, 10, 20, 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700,
    800, 900, 1,000, 1,500, 2,000, 2,500, 3,000 and 3,400µs.
  • Step: 0.1µs (from -20ms to +999.9ms), 1µs (from 1,000ms to 3,400ms)

Probe delay:

  • P-delay range: 0.0 to 99.99µs
  • Step: 0.01µs

Sound velocity in material:

  • Sound velocity range: 1,000 to 9,999m/s
  • Seven fixed velocities or stages: 2,260, 2,730, 3,080, 3,230, 4,700, 5,900 and 6,300
  • Step: 1m/s

Working methods: Single probe (P/R), dual probe (transceiver) or transmission probe

Frequency ranges: Low: 0.2 to 1MHz, middle: 0.5 to 4MHz, high: 2 to 20MHz, three steps optional

Gain:

  • Range: 0 to 110dB
  • Step: 0.0, 0.2, 0.5, 1, 2, 6 and, 12d

Linear suppression: 0% to 80% of screen height, step:1%

Vertical linear error: Less than 3%

Horizontal linear error: Less than 1% within scanning range

Detection sensitivity margin: ≥60dB

Dynamic scope: ≥32dB

Alarm: Traveling-wave alarm, evanescent-wave alarm

Monitoring gate:

  • Two gates represented by a horizontal thick line with adjustable start point, width and height.
  • Starting point(mm): horizontal pixels from 0 to 208 with the display value relating to scanning range.
  • Step(mm): quantity corresponding to one pixel (relating to scanning range)
  • Width(mm): horizontal pixels from 4 to 212 with the display value relating to scanning range.
  • tep(mm): quantity corresponding to one pixel (relating to scanning range)
  • Height: vertical scale from 2% to 90%
  • Step: 1%

Display:

  • EL highlight dot matrix
  • 4 background colors available

A-Scan display:

  • Full screen or partial
  • Freezing and unfreezing of image

Wave display: All waves

Detecting channels: 10

Data storage:

  • 300 A-Scan waveforms (30 for each channel)
  • 30,000 thickness values (300 groups)

Communication port: RS232

Measuring Units: mm or in; time in µs

Power adaptor:

    • Input: 100 to 240VAC @ 50 Hz to 60Hz
    • Output: 9 to12VDC @ 3 to 4A

Power: Four 3.6V lithium batteries, 4,000mAhr

Ambient temperature: 0 to 40⁰C

Ambient humidity: 20 to 90%RH

Interface: BNC

Dimensions of processor: 240 × 173 × 50mm

Weight of processor: 2.2kg

 

Optional Items

Angle-beam probe
0 degree – 2 MHz or 4 MHz

Angle-beam probe
45 degree – 2 MHz or 4 MHz

Angle-bean probe
60 degree – 2 MHz or 4MHz

Angle-beam probe
70 degree – 2 MHz or 4 MHZ

Normal probe: T/R 5MHz
1/4″ diameter

Normal probe: single 5MHz
1/4″ diameter

Normal probe: single 1MHz
1/4″ diameter

Probe cable – single with suitable connection

Probe cable – dual with suitable connection

Calibration block V1 for steel – metric units

calibration block V2 for steel- metric units

ASME block for steel (1/2″ T) – metric units

ASME block for steel (3/4″ T) – metric units

—-> Go back to our line of Portable Testers here

Print Friendly, PDF & Email

Reviews

There are no reviews yet.